Home / Statistics hub
Outage and readiness numbers, sourced and dated
Every figure this site runs on, collected on one page so it can be checked and cited: how long US outages actually last, how long food stays safe without power, the water and food storage standards, and the Hawaii numbers behind the catchment pages. Each statistic carries its source and its date or edition next to the number, and a link to the page on this site that works it through.
Affiliate disclosure: Power & Pantry is reader-supported, and some links on this site are affiliate links that may earn us a commission at no extra cost to you. No product is sold from this page, and no affiliate links are live on it. See the About page for how we work.
How to read this page. Figures checked November 2026. Agency and university extension figures are attributed to the agency or the extension service. Manufacturer figures are labeled as the maker's, and manufacturer claims are labeled as claims. Figures computed on this site show their inputs, the same way the article pages show them. A figure whose source or date cannot be stated is not printed; the gaps section near the end names the numbers this page does not carry. This hub is refreshed quarterly: every statistic is re-dated or replaced at each refresh.
The outage itself: US grid reliability
The US Energy Information Administration (EIA) collects reliability data from utilities every year on Form EIA-861 and publishes it in the Electric Power Annual. Three indexes do the work, in EIA's own definitions: SAIDI is the minutes of non-momentary interruption per year the average customer experienced, SAIFI is the number of those interruptions per year, and CAIDI is the average minutes it takes to restore one. Utilities reporting under the IEEE 1366 standard also split every figure two ways, with and without major event days, the days when storm damage passes a statistical threshold. The two columns tell different stories, and both are printed here.
| Data year | Minutes without power per customer, all events (SAIDI) | Minutes without power per customer, without major event days (SAIDI) |
|---|
| 2015 | 209 | 117 |
| 2016 | 268.4 | 119.8 |
| 2017 | 505.9 | 117 |
| 2018 | 349.2 | 121.4 |
| 2019 | 295.5 | 122.2 |
| 2020 | 456.1 | 116 |
| 2021 | 475.8 | 125.7 |
| 2022 | 333 | 131.1 |
| 2023 | 366.6 | 123.9 |
| 2024 | 662.6 | 131.6 |
| 2025 | 269.2 | 125.3 |
US Energy Information Administration, Electric Power Annual, Table 11.1, utilities reporting under the IEEE method, Form EIA-861 data, checked November 2026.
Read the trend plainly. The routine part of US outage time has barely moved in a decade: without major event days, the average customer lost between 116 and 131.6 minutes a year in every year from 2015 to 2025, about two hours a year. The all-events column is a weather series more than a grid series. It swings from 209 minutes in 2015 to 662.6 minutes in 2024, about 11 hours and the highest figure in the series, and back down to 269.2 minutes in 2025.
| Figure | Number | Source and date | Worked through on |
|---|
| Share of 2024 outage minutes that fell on major event days | About 80 percent | Computed from EIA Table 11.1: (662.6 minus 131.6) divided by 662.6, checked November 2026 | Generator safety |
| Interruptions per customer, 2025 (SAIFI) | 1.34 with major events; 1.08 without | EIA, Electric Power Annual, Table 11.1, IEEE method, checked November 2026 | Generator wattage calculator |
| Average time to restore one interruption, 2025 (CAIDI) | 201 minutes with major events; 116 minutes without | EIA, Electric Power Annual, Table 11.1, IEEE method, checked November 2026 | Fridge runtime |
| Hawaii minutes without power per customer | 282.1 minutes (about 4.7 hours) in 2025; 320.6 minutes (about 5.3 hours) in 2024 | EIA, Electric Power Annual, Table 11.3, any reporting method, checked November 2026 | Hawaii catchment guide |
| Hawaii interruptions per customer (SAIFI) | 2.02 in 2025 and 2.62 in 2024, against US figures of 1.34 and 1.52 | EIA, Electric Power Annual, Table 11.3, any reporting method, checked November 2026 | Hawaii catchment guide |
| Hawaii routine outage time, without major event days | 187.5 minutes in 2025, against a US figure of 120.8 minutes | EIA, Electric Power Annual, Table 11.3, any reporting method, checked November 2026 | Hawaii catchment guide |
The Hawaii rows carry one caution the table itself states: EIA's state table uses any reporting method and covered 99.7 percent of Hawaii customers in 2025 and 99.9 percent in 2024. Read together, the Hawaii figures describe a state whose customers lose power more often than the national average, for fewer total minutes in the hurricane year 2024, and whose ordinary, non-storm outage time runs well above the national ordinary figure. That combination, frequent shorter outages on ordinary days, is the pattern the catchment and backup power pages on this site are built around.
Food safety windows when the power is out
| Figure | Number | Source and date | Worked through on |
|---|
| How long a closed refrigerator keeps food cold | About 4 hours | FoodSafety.gov food safety during a power outage guidance, checked November 2026 | Fridge runtime |
| How long a full freezer holds safe temperatures | About 48 hours | FoodSafety.gov, checked November 2026 | Fridge runtime |
| How long a half-full freezer holds safe temperatures | About 24 hours | FoodSafety.gov, checked November 2026 | Fridge runtime |
| The refrigerator safety line | 40 degrees F: food held above it for more than a short window is discarded | FoodSafety.gov, checked November 2026 | Fridge runtime |
The loads this site sizes by
These are this site's published planning figures. Each one shows its inputs on the page that works it through, and every runtime on the site is arithmetic on them, not a measurement.
| Figure | Number | Source and date | Worked through on |
|---|
| Typical refrigerator load | 1,800 watt-hours per day: a 150 W running draw at about a 12-hour daily duty cycle | This site's planning model, from the calculator presets, November 2026 | Fridge runtime |
| Essentials load (fridge, lights, phones, router) | 2,535 watt-hours per day | This site's planning model, November 2026 | Best portable power stations |
| Near-whole-home load | 5,435 watt-hours per day | This site's planning model, November 2026 | Best portable power stations |
| Usable share of a power station's rated capacity | Rated watt-hours times 0.85, disclosed on every page that uses it | This site's planning model, November 2026 | Generator wattage calculator |
| Solar harvest planning figure | 3.44 watt-hours per day per rated watt: 4 effective sun hours with a 14 percent loss allowance | Computed on this site from EcoFlow's published planning method, which uses the National Renewable Energy Laboratory PVWatts loss default, November 2026 | Folding solar panels |
| Panel output during daylight hours | About 75 percent of rated power | EcoFlow's published collection guidance, checked November 2026 | Folding solar panels |
| Panel size that covers the fridge load alone | About 525 rated watts | Computed on this site: 1,800 divided by 3.44, November 2026 | Folding solar panels |
Generator safety, in numbers
| Figure | Number | Source and date | Worked through on |
|---|
| US deaths per year from portable generator carbon monoxide | About 100 | US Consumer Product Safety Commission, Non-Fire Carbon Monoxide Deaths report, 2022 annual estimates, cited in CPSC release 26-149, December 12, 2025 | Generator safety |
| All-source non-fire carbon monoxide harm per year | More than 400 deaths, more than 100,000 emergency department visits, more than 14,000 hospitalizations | Centers for Disease Control and Prevention carbon monoxide guidance, checked November 2026 | Generator safety |
| Minimum generator placement distance | At least 20 feet from the house and from windows, doors, and vents, exhaust pointed away | CPSC generator safety guidance; CDC carbon monoxide guidance, checked November 2026 | Generator safety |
| Scope of the PGMA G300-2023 carbon monoxide shutoff standard | Portable generators up to 15 kW, including inverter models, manufactured on or after January 1, 2025 | Portable Generator Manufacturers' Association standard G300-2023, checked November 2026 | Generator safety |
What electricity costs
| Figure | Number | Source and date | Worked through on |
|---|
| US average residential electricity price | 18.16 cents per kWh | EIA, Electric Power Monthly, August 2026 | AWG vs catchment |
| Hawaii average residential electricity price, the highest in the US | 47.18 cents per kWh | EIA, Electric Power Monthly, August 2026 | Catchment filters and UV |
Batteries and starting watts
| Figure | Number | Source and date | Worked through on |
|---|
| LiFePO4 cell cycle life and thermal runaway point | 2,000 or more cycles; thermal runaway at about 270 degrees C | Battery University published cell averages, checked November 2026 | LiFePO4 vs lithium-ion |
| NMC cell cycle life and thermal runaway point | 1,000 to 2,000 cycles; thermal runaway at about 210 degrees C | Battery University published cell averages, checked November 2026 | LiFePO4 vs lithium-ion |
| The end-of-life threshold behind published cycle counts | 80 percent of original capacity for Bluetti, EcoFlow, and Goal Zero; 70 percent for Jackery LiFePO4 models | The makers' published specifications, checked November 2026 | LiFePO4 vs lithium-ion |
| The lithium charging floor | No charging below freezing, 0 degrees C, on any chemistry in a consumer power station | The makers' published manuals, checked November 2026 | LiFePO4 vs lithium-ion |
| Motor starting current | An across-the-line motor can draw up to 6 times its full-load current at start | US Department of Energy motor guidance, checked November 2026 | Starting watts vs running watts |
| Published refrigerator starting watts, same appliance class | 800 W (this site's calculator preset) to 2,200 W (Generac's sizing chart); Honda's chart lists 1,200 W | Generac and Honda published sizing charts, checked November 2026 | Starting watts vs running watts |
Water storage standards
| Figure | Number | Source and date | Worked through on |
|---|
| The federal storage floor | 1 gallon per person per day, for drinking and sanitation together | Ready.gov water guidance; CDC emergency water guidance, checked November 2026 | How much water to store |
| How many days the federal guidance asks for | At least a 3-day supply; try for a 2-week supply | CDC emergency water supply guidance, checked November 2026 | How much water to store |
| Hawaii's readiness standard | 14 days of supplies, raised from 7 days in 2017 | Hawaii Emergency Management Agency, 2 Weeks Ready program, checked November 2026 | How much water to store |
| What a gallon of water weighs | 8.34 pounds | Standard water density figure used by the CDC and this site's calculators, checked November 2026 | Water storage calculator |
| Rotation for water you filled yourself | Replace about every 6 months | CDC emergency water supply guidance; Ready.gov, checked November 2026 | Water storage containers |
| Storage temperature for stored water | 50 to 70 degrees F, away from sunlight and toxic substances | CDC emergency water supply guidance, checked November 2026 | Water storage containers |
| Container sanitizing solution | 1 teaspoon of unscented bleach per quart of water | CDC emergency water supply guidance, checked November 2026 | How much water to store |
| Hawaii households that believed they were prepared | 56 percent believed they were prepared; about 12 percent actually had 14 days of water, food, and medicine | University of Hawaii study of about 1,000 Hawaii households, as cited in CTAHR catchment guidance, checked November 2026 | Hawaii catchment guide |
Water treatment, in numbers
| Figure | Number | Source and date | Worked through on |
|---|
| Boiling for disinfection | A rolling boil for 1 minute; 3 minutes above 6,500 feet | CDC emergency water treatment guidance, checked November 2026 | Filter straws and portable purification |
| What portable filters cannot do | No portable membrane filter removes viruses | CDC guidance on water filters and treatment, checked November 2026 | Filter straws and portable purification |
| Pore sizes that remove bacteria and parasites | Absolute pore size of 0.3 micron or smaller for bacteria; 1 micron absolute or smaller for parasites such as Giardia and Cryptosporidium | CDC guidance on water filters, checked November 2026 | Filter straws and portable purification |
| The NSF/ANSI 53 cyst reduction bar | At least 99.95 percent reduction of parasitic cysts | Text of NSF/ANSI Standard 53, checked November 2026 | Catchment filters and UV |
| What the NSF/ANSI numbers mean | 42 covers aesthetic effects; 53 covers health effects such as lead, cysts, and total PFAS, only as listed; 401 covers emerging compounds; 372 covers lead-free materials | NSF/ANSI standards as listed by the certifying bodies, checked November 2026 | Gravity filters after Berkey |
| Cost of a certified gallon | Elements certified under NSF/ANSI 53 for lead and total PFAS run $1.05 to $1.38 per certified gallon; the cheapest elements to run are certified only under 42 and 372 | IAPMO certification listings and the makers' published prices and capacities, checked November 2026 | Berkey alternatives |
| The Berkey stop-sale, dated | EPA stop-sale orders in December 2022 (a distributor) and May 8, 2023 (Berkey International); the First Circuit declined to block the order on September 18, 2026. A pesticide registration dispute, not a safety finding; owning and using the elements was never banned | US Environmental Protection Agency orders under FIFRA; US Court of Appeals for the First Circuit, No. 24-1917, September 18, 2026 | Gravity filters after Berkey |
Catchment, in numbers
| Figure | Number | Source and date | Worked through on |
|---|
| People in Hawaii who depend on rainwater catchment | 30,000 to 60,000, the majority on Hawaii Island | University of Hawaii CTAHR catchment guidelines, revised 2020; Hawaii Department of Health catchment pages, checked November 2026 | Hawaii catchment guide |
| The harvest constant | 0.623 gallons per square foot of roof per inch of rain (CTAHR's guidelines use 0.625) | CTAHR catchment guidelines, revised 2020 | Catchment calculator |
| One roof, one wet district, one year | About 62,300 gallons before losses from a 1,000 square foot roof in a 100-inch rainfall district | Computed on this site: 1,000 times 100 times 0.623, November 2026 | AWG vs catchment |
| Catchment household water use | 30 to 50 gallons per person per day, against a national average near 120 | CTAHR catchment guidelines, revised 2020 | AWG vs catchment |
| Hawaii DOH screening levels for catchment water | Turbidity at or below 5 NTU; E. coli absent; lead at or below 0.010 mg/L; copper at or below 1.3 mg/L | Hawaii Department of Health, Safe Drinking Water Branch catchment guidance, checked November 2026 | Catchment maintenance |
| The subsidized lead and copper test | Once a year per home; the owner pays shipping and $25 for the analyses | Hawaii Department of Health, checked November 2026 | Catchment maintenance |
| UV disinfection doses | NSF/ANSI 55 Class A delivers at least 40 mJ/cm²; Class B delivers 16 mJ/cm² and is the supplemental class for water already deemed acceptable | Text of NSF/ANSI Standard 55, checked November 2026 | Catchment filters and UV |
| UV lamp rated life | 9,000 hours, about one year of continuous operation; output fades while the lamp still glows | Viqua owner's manuals, checked November 2026 | Catchment maintenance |
| A year of catchment upkeep | About $217 to $296 in parts and testing, before shipping | Computed on this site from Pentair's February 2026 published price list, Viqua lamp prices at two retailers, and the DOH test fee, checked November 2026 | Catchment maintenance |
| County water, per gallon charges | $4.53 per 1,000 gallons in total per-gallon charges for Hawaii County water | Hawaii County Department of Water Supply rate brochure, effective March 1, 2026 | AWG vs catchment |
| What a gallon of machine-made water costs in energy | Maker figures of 0.91 to 1.51 kWh per gallon at rated conditions for home atmospheric water generators; field reports put real installations at about 8.5 kWh per gallon | Aquaria and Watergen published spec sheets, checked November 2026; the 8.5 figure is field reports collected in this site's November 2026 research, labeled as reports, not ratings | AWG vs catchment |
Food storage, in numbers
| Figure | Number | Source and date | Worked through on |
|---|
| One published one-year food basket | 476 pounds per person per year, about 2,090 to 2,114 kcal per day: grains 247 lb, legumes 62, milk 60, sugar 70, salt 8, fats 29 | Brigham Young University food storage recommendations, revised June 2024 | How much food storage per person |
| A second published one-year basket | 563 pounds per person per year, about 2,451 kcal per day | Utah State University Extension basic one-year supply, checked November 2026 | How much food storage per person |
| The monthly minimum in a third system | 25 pounds of grains plus 5 pounds of dry beans per adult per month | The Church of Jesus Christ of Latter-day Saints food storage guidance, checked November 2026 | How much food storage per person |
| Home freeze-dried food, extension window | Safe and stable for 10 to 15 years in mylar with oxygen absorbers; plan to eat it within 5 to 10 years | Utah State University Extension, checked November 2026 | Freeze-dried shelf life |
| What storage temperature does to shelf life | Shelf life halves with every 10.8 degrees F rise in storage temperature | Utah State University Extension, citing USDA research, checked November 2026 | Freeze-dried shelf life |
| Home-dried food storage window | 4 months to 1 year for dried foods; home-dried jerky 1 to 2 months | National Center for Home Food Preservation; USDA Food Safety and Inspection Service, checked November 2026 | Freeze dryer vs dehydrator |
| Energy per batch, preserving | About 26 kWh for a mid-range freeze dryer batch; about 7.2 kWh for a 12-hour dehydrator load at rated draw, an upper bound | Computed on this site from Harvest Right's and Excalibur's published draw and cycle figures, November 2026 | Freeze dryer vs dehydrator |
| Cost per pound preserved, at US planning electricity rates | $0.76 per pound freeze-dried against $0.17 per pound dehydrated, for a household preserving 500 pounds a year | Computed on this site with inputs shown on the page, November 2026 | Freeze dryer vs dehydrator |
| Where an oxygen absorber leaves a sealed bag | 0.01 percent oxygen or less, the rest effectively nitrogen | Utah State University Extension, Oxygen Absorbers, 2011 | Mylar bags and oxygen absorbers |
| The oxygen inside a full gallon of airy food | About 596cc, more than the standard 500cc packet a gallon set ships | Computed on this site: 3,785cc times a 75 percent air fraction times 0.21, November 2026 | Mylar bags and oxygen absorbers |
| Manufacturer claim: freeze-dried shelf life | Up to 25 years, for food sealed in mylar with oxygen absorbers | Harvest Right, the manufacturer's claim, checked November 2026. No extension body certifies a home batch for 25 years | Freeze-dried shelf life |
| Manufacturer claim: commercial freeze-dried meals | A 30-year taste guarantee | Mountain House, the manufacturer's claim, checked November 2026 | Freeze-dried shelf life |
Warmth, washing, and hygiene, in numbers
| Figure | Number | Source and date | Worked through on |
|---|
| Electric blanket and space heater draws | About 60 W for a single blanket and 100 W for a double; 750 to 1,500 W for a space heater | US Department of Energy, Energy Saver guidance, checked November 2026 | Heated blanket runtime |
| Fires from heating pads and electric blankets | Almost 500 fires per year in the US, almost all involving blankets more than 10 years old | Electrical Safety Foundation International, checked November 2026 | Heated blanket runtime |
| What one home shower spends | About 20 gallons for an 8-minute shower | Computed on this site from the US EPA WaterSense standard showerhead rate of 2.5 gallons per minute, November 2026 | Sanitation beyond the toilet |
| The hygiene water budget | About 0.85 gallons per person per day: half a gallon for a basin wash, about a quarter for a shower in rotation, about a tenth for handwashing | This site's labeled planning figures, November 2026 | Sanitation beyond the toilet |
| Handwashing, the federal version | Soap and water for at least 20 seconds; the fallback is an alcohol-based sanitizer of at least 60 percent alcohol, which the CDC states does not work well against norovirus | CDC emergency hygiene guidance, checked November 2026 | Emergency toilet |
| The two-bucket toilet, priced | The supplies can often be gathered for under $20 | Oregon State University Extension, Survival Basics: Sanitation and Waste Management, EM 9334, checked November 2026 | Emergency toilet |
| The burial setback for waste | Never bury waste within 100 feet of a water source | Oregon State University Extension, EM 9334, checked November 2026 | Emergency toilet |
Radios and shielding, in numbers
| Figure | Number | Source and date | Worked through on |
|---|
| The GMRS license | $35, lasts 10 years, no exam, and covers the holder's immediate family | Federal Communications Commission, Part 95 rules and fee schedule, checked November 2026 | Best emergency radios |
| The NOAA Weather Radio network | More than 1,000 transmitters, broadcasting around the clock on seven frequencies between 162.400 and 162.550 MHz | National Weather Service, checked November 2026 | Best emergency radios |
| Handheld two-way range to plan on | About half a mile to 2 miles in normal conditions | Midland's own published FAQ, checked November 2026; BTECH's published planning figure for a 5 W handheld is 0.9 to 1.7 miles | Off-grid communication options |
| Mesh radio relay limit | A default of 3 hops, settable to no more than 7 | Meshtastic project documentation, checked November 2026 | Off-grid communication options |
| The government's protection level for stored spare electronics | At least 20 dB of protection, with foil wrap or a Faraday container as the named methods | Department of Homeland Security and CISA, EMP Protection and Resilience Guidelines, Version 2.2, February 5, 2019 | Do faraday bags actually work? |
| What decibels mean in power | 20 dB of attenuation cuts signal power by a factor of 100; 40 dB by 10,000; 60 dB by 1,000,000; 80 dB by 100,000,000 | DHS EMP Protection and Resilience Guidelines, Table E-1, Version 2.2, February 5, 2019 | Do faraday bags actually work? |
| Same fabric, two prices | One maker's phone pouch at $23 and its walk-in shielded tent from $20,990 carry the same stated attenuation figure, 80 dB or more | MOS Equipment, Mission Darkness store pages, checked November 2026. The figures are the maker's stated attenuation, from its published lab results | Faraday cage vs faraday bag |
Numbers this page does not carry
A statistics page earns its citations partly by what it refuses to print. These gaps are named here so no reader assumes a figure exists where none was verified:
- Outage duration for Hawaii Island, or for any single island. EIA publishes Hawaii reliability at state level only, so the Hawaii rows above are state figures. No island-level figure is printed, because no primary source publishes one we could verify.
- A standard price for professional catchment tank cleaning. Neither CTAHR nor any maker publishes one, so the upkeep total above covers parts and testing only, exactly as the maintenance page states.
- Your own refrigerator's starting watts. The published charts span 800 to 2,200 W for the same appliance class. The figure that governs your fridge is the locked-rotor amps on its own nameplate, multiplied by its voltage, and no hub page can print it for you.
- Any figure for how many households buy readiness gear in a year. The fan-out research behind this site counted search phrases, not purchases, and search counts are not sales. No market-size number is printed.
Citing this page: Power & Pantry, "Outage and readiness numbers, sourced and dated," powerandpantry.com/statistics/, figures checked November 2026. Each statistic names its own source next to the number; cite the original source where your use allows it, and this page for the collection. The page is refreshed quarterly, and the checked date above moves with each refresh.
Our data basis: the outage series and the Hawaii rows are the US Energy Information Administration's, from the Electric Power Annual, Tables 11.1 and 11.3, built on Form EIA-861 utility reports, checked November 2026. Electricity prices are EIA's Electric Power Monthly for August 2026. Food safety windows are FoodSafety.gov's. Generator figures are the Consumer Product Safety Commission's and the CDC's. Water standards are Ready.gov's and the CDC's; the Hawaii standard is the Hawaii Emergency Management Agency's. Catchment figures are the University of Hawaii CTAHR guidelines (revised 2020), the Hawaii Department of Health's catchment and Safe Drinking Water Branch pages, NSF/ANSI Standards 53 and 55, and Viqua's and Pentair's published documents. Food storage figures are Brigham Young University's (revised June 2024), Utah State University Extension's, the National Center for Home Food Preservation's, and USDA's. Radio figures are the FCC's, the National Weather Service's, the Meshtastic project's, and the makers' own published pages. Shielding figures are the Department of Homeland Security and CISA EMP guidelines, Version 2.2, February 5, 2019, and MOS Equipment's published lab results. Manufacturer claims are labeled as claims where they appear. Computed figures show their inputs in the table. Nothing on this page is presented as measured or tested by us.