Running watts are what an appliance draws once it is up and going, hour after hour. Starting watts, also called surge watts, are the much larger burst a motor draws for the first few seconds while it gets turning. A load with no motor, a kettle, a lamp, a heater, has only the first number: it starts at its running watts and stays there. A load with a motor, a fridge, a pump, a furnace fan, has both, and the second number is the one that decides whether your generator or power station can start it at all.
Affiliate disclosure: Power & Pantry is reader-supported, and some links on this site are affiliate links that may earn us a commission at no extra cost to you. This page links to our own calculator and comparisons, and to the Honda, Generac, and U.S. Department of Energy pages it cites. See the About page for how we work.
The definitions are simple. The published numbers are not.
Ask four competent sources for the two numbers of the same appliance, a household refrigerator, and you get four different answers:
| Source | Running watts | Starting watts | Start as a multiple of running |
|---|---|---|---|
| Our calculator's preset | 150 | 800 | About 5 times |
| Honda's wattage chart (Energy Star fridge or freezer) | 132 to 192 | 1,200 | About 6 to 9 times |
| Honda's worked sizing example | 200 | 1,600 | 8 times |
| Generac's support page | 700 | 2,200 | About 3 times |
Nobody in that table is lying. They are describing different fridges, a small efficient model against a big one, and rounding at different points. Honda cannot even agree with itself: its chart gives a quarter-horsepower furnace fan a 1,000 W start, and its worked example gives the same fan a 1,600 W start, on the same 600 W running figure. Treat every published chart, including ours, as a planning figure with a wide error band. The only starting figure that belongs to your exact appliance is printed on that appliance, and the section below on nameplates shows where it lives.
Our own preset sits at the low end of the range on purpose, and it is worth saying why. It is paired with the runtime model in our fridge runtime article: a typical fridge that draws 150 W while its compressor runs and runs about half the day. If your fridge is large, old, or a side-by-side, plan on the Honda or Generac end of the table instead, and let the surge check, not the runtime table, have the final word.
Why a motor draws more at the start
A motor that is standing still is, electrically, a different device from the same motor turning. The U.S. Department of Energy's motor systems guidance describes starting current as having two parts: an instantaneous peak inrush that arrives within half an AC cycle, and a locked-rotor current that stays near its starting value while the motor accelerates, falling only as the motor approaches operating speed. Locked rotor is the electrician's term for the moment the switch closes and the shaft has not yet begun to move: the motor draws as if it were stalled, because for that moment it is. The same department's pumping guidance puts the size of it plainly: an induction motor started across the line can draw as much as six times its full-load current during start-up.
You can see the two currents printed side by side on real equipment. A current Trane submittal sheet for residential air conditioners lists each compressor with an RLA, its rated running current, and an LRA, its locked-rotor current. One 3-ton model reads 13.5 amps running and 83 amps locked-rotor. At the 230 volts on the same sheet, that is about 3,100 W to run and about 19,100 W at the instant of starting, roughly six times as much, matching the Department of Energy's figure. A central air conditioner is a hardwired 240 V load that no portable station in our comparisons will ever run; it is here because its nameplate is the clearest printed proof that the start and the run are different numbers, published by the maker, for the same machine.
How long does the burst last? Generac's support page, which defines surge wattage for its own generators, says the extra demand typically lasts two to three seconds before the appliance settles back to its running wattage. That is the whole event, switch-on to full speed. It is long enough that a power source has to genuinely supply it, and short enough that it barely registers in energy terms: a start is a watts problem, not a watt-hours problem.
Which loads surge, and which do not
The dividing line is the motor. Anything that has to get something spinning surges. Anything that simply turns electricity into heat or light does not. From Honda's published wattage chart, checked in November 2026:
| Load | Running watts | Starting watts | Why |
|---|---|---|---|
| Refrigerator or freezer (Energy Star) | 132 to 192 | 1,200 | Compressor motor |
| Furnace fan, 1/4 hp | 600 | 1,000 | Blower motor |
| Sump pump, 1/2 hp | 1,050 | 2,150 | Pump motor |
| Window air conditioner, 10,000 BTU | 1,500 | 2,200 | Compressor and fan motors |
| Garage door opener | 720 | 1,420 | Motor |
| Portable fan | 40 | 120 | Small motor, still a motor |
| Coffee maker | 600 | 600 | Heating element, no motor |
| Electric water heater | 4,500 | 4,500 | Heating element, no motor |
| Lights and televisions | As marked on the bulb or set | Same | No motor |
One label trap hides in Honda's chart. The microwave rows list a "1,000 watt" oven at 1,500 W starting and 1,500 W running. The 1,000 W on a microwave's box is its cooking power, what it delivers into food; the 1,500 W is what it draws from the wall. There is no surge gap to speak of, but there is a 50 percent gap between the number in the product name and the number your power source sees. The same habit, naming a product for the flattering figure, runs through this whole category, generators included, as the supply-side section below shows.
There is no standard multiplier
Advice columns love a rule of thumb: starting watts are two times running watts, or three times. The tables above already break both rules, in both directions. The window air conditioner starts at about one and a half times its running draw. The Energy Star fridge starts at six to nine times. And the multiple is not even fixed by horsepower. Honda's industrial motor table gives three motors of the same half horsepower, each running at 600 W, three different starts depending on how the motor is built:
| Motor type, 1/2 hp (Honda's industrial motor table) | Running watts | Starting watts |
|---|---|---|
| Split phase | 600 | 2,600 |
| Capacitor start, induction run | 600 | 1,800 |
| Capacitor start, capacitor run | 600 | 1,300 |
Same size, same running draw, a two-to-one spread in starting draw, decided by a design detail no shopper can see from the shelf. That is why this page will not give you a multiplier. If a figure matters, it has to come from the appliance itself, which is the next section.
Read the number off your own appliance
Compressors and motor equipment carry the answer on their rating plates. The plate prints a running current (marked RLA or FLA) and a locked-rotor current (marked LRA). Starting watts are the locked-rotor amps multiplied by the voltage on the same plate:
- Starting watts = LRA × volts. On a 120 V appliance, every locked-rotor amp is 120 W of start.
- Running watts ≈ RLA × volts at full load, an upper-end running figure rather than an average.
Run the published fridge figures backwards through that arithmetic and the disagreement in the first table becomes concrete. Our preset's 800 W start implies a locked-rotor draw of about 6.7 amps. Honda's chart implies 10 amps, its example about 13 amps, and Generac's figure about 18 amps. Those are different compressors, and yours is one specific compressor with one specific plate. The Department of Energy's motor guidance makes the same point from the motor side: nameplates carry a locked-rotor code letter that states the starting draw per horsepower, because the industry expects the figure to be read off the machine, not guessed from a chart.
If your fridge's plate gives no LRA, and many kitchen appliances print only a single amp rating, use a published chart and plan on the high end of it. The cost of planning on 2,200 W for a fridge that starts at 1,200 W is a slightly larger power source. The cost of planning on 800 W for a fridge that starts at 2,200 W is a fridge that does not start.
The same two numbers on the box that feeds them
Generators and power stations carry the same pair of numbers, under at least three different pairs of labels, which is half of why buyers mix them up.
Gas generators print a rated wattage, what they can deliver all day, and a maximum, what they can deliver for a start. Honda's EU2200i specification reads "2,200 W max, 1,800 W rated," and the model is named for the maximum. When a generator is advertised by one number, it is almost always the starting figure, and the running figure, the one your continuous load has to fit inside, is the smaller one on the specification sheet.
Power stations print a continuous rating and a surge rating. On the stations in our comparisons the surge figure is typically double the continuous one: the Bluetti Elite 100 V2 is rated 1,800 W continuous with a 3,600 W surge, and the EcoFlow DELTA Pro 3 is rated 4,000 W with an 8,000 W surge. One gap is worth naming: on the product pages we checked in November 2026, neither maker states how long its surge rating can be held. The appliance side of the number has a published duration, Generac's two to three seconds. The supply side arrives with no time attached, and a shopper has no way to compare one brand's surge claim against another's on duration. Buy surge headroom with that in mind.
Boost modes are not surge. Bluetti's Power Lifting and EcoFlow's X-Boost raise the ceiling for resistive loads above the continuous rating by trimming the output voltage. EcoFlow's own manual describes X-Boost as more suitable for heating devices, and not for devices with voltage protection, which may stop working at the reduced voltage. A boost mode can keep a 2,600 W kettle heating on a 1,800 W station. It does not add a watt of motor-starting ability, because a starting motor is not a resistive load and does not accept reduced voltage as a substitute. Our station comparison labels boost wattage separately from surge wattage in its grid for exactly this reason.
Sizing with the two numbers
The method every manufacturer guide converges on: add the running watts of everything that will be on at once, then add the extra that the single biggest start needs on top of its own running watts. Only one extra, because only one motor starts in any given moment, as long as you let them start one at a time.
Honda works the same idea in its own sizing example. Five loads, a fridge, a furnace, lights, a television, and a microwave, total 1,400 W of continuous need, with the largest occasional demand, a fridge or furnace start, at 1,600 W. Honda's conclusion: a 3,000 W generator runs everything easily, and the load could be run on less by starting the big motors at separate times. Honda calls that power management, and it is the cheapest capacity there is. One arithmetic note, because the two methods on this page differ slightly: Honda's addition carries the starting appliance's running watts inside both of its totals, a small built-in cushion, while our calculator adds only the start's extra above its running watts. On Honda's own example the difference is 200 W, and either method lands on the same generator class.
Here is the method on our own calculator's presets, against a real station's published pair of numbers, the Elite 100 V2's 1,800 W continuous and 3,600 W surge:
| Appliance mix (calculator presets) | Running total | Biggest start's extra | Peak the source must meet |
|---|---|---|---|
| Fridge (150 / 800 W) + freezer (100 / 600 W) + LED lights (60 W) + router (10 W) | 320 W | 650 W (fridge) | About 970 W |
| The same mix + a 1/2 hp well pump (1,000 / 2,100 W) | 1,220 W | 1,100 W (pump) | About 2,320 W |
| The well pump mix, if the fridge and the pump start in the same moment | 1,220 W | Both starts at once: 800 + 2,100 W | About 2,970 W |
Read the middle row carefully, because it is the row that teaches the concept. The running total, 1,220 W, fits inside the station's 1,800 W continuous rating with room to spare. The peak, about 2,320 W, does not fit inside the continuous rating at all; it fits inside the 3,600 W surge rating, which is where it belongs, because it lasts seconds. The third row is the failure mode the one-start-at-a-time rule exists to prevent: two motors starting together stack their full starting watts, and the peak climbs toward the surge ceiling. Staggering starts, or simply not switching two motor loads on in the same second, is worth more than a size class of equipment.
Our generator wattage calculator runs this exact arithmetic on your own appliance list: it totals the running watts, adds the largest start's extra, and reports the starting watts your inverter must handle, alongside the daily watt-hours that decide runtime. If you are sizing for a gas generator instead, the load math is identical, and the generator safety page covers the placement and carbon monoxide rules that come with fuel.
What happens when the surge number is too small
Nothing dramatic, which is its own problem. The motor hums, strains, and does not come up to speed, or the power source ends the argument first: a generator's breaker trips, or a power station's overload protection cuts the output. Generac's sizing guidance warns that planning without the surge risks tripping breakers or overloading the generator, and EcoFlow's manuals describe overload protection as the failure its boost feature exists to avoid. The fridge then sits silent, and because the battery still shows a healthy charge, the failure looks like a capacity problem. It is not. The watt-hours were fine. The watts, for three seconds, were not.
Placeholder: matched offers
Matched offers (placeholder). When this site's affiliate programs are approved, this block will list power stations whose continuous and surge ratings cover the loads this page works through, with dated prices. Until then there are no purchase links on this page. If you are shopping now, the station comparison prints both ratings for every model it covers, surge labeled separately from boost wattage, and the Bluetti vs EcoFlow comparison works the long-outage version of the same choice.
Questions people actually ask
Are starting watts, surge watts, and peak watts the same thing?
Yes. Three labels for one burst: the extra power a motor draws while it gets turning. Generac uses "surge" and "starting" interchangeably in its own support pages. On the supply side the same figure is also sold as "maximum" watts (Honda's wording) against "rated" watts. When two products seem to disagree, check which label each number wears before comparing them.
How long do starting watts last?
Generac puts the extra demand at typically two to three seconds, after which the appliance settles to its running wattage. The Department of Energy's motor guidance adds the texture: the current sits near its locked-rotor value while the motor accelerates and falls as it nears full speed. Either way, the start is measured in seconds, which is why it governs watts and barely touches watt-hours.
How do I find my own fridge's starting watts?
Look for the rating plate on the fridge or its compressor and find the LRA figure; multiply it by the voltage on the plate (120 V for a household fridge) and you have the starting watts the maker itself published. If the plate shows only one amp number, fall back on a manufacturer chart, Honda's or Generac's, and plan on the higher figure, for the reason the first table on this page shows.
Does a bigger surge rating make a power station run things longer?
No. Surge is measured in watts and answers a three-second question. Runtime is measured in watt-hours and answers an all-night question. A station can have a towering surge rating and a small battery, or a large battery and a modest surge rating. The fridge runtime article works the watt-hours side; this page works the watts side; a sound purchase passes both tests.
Can a boost mode like X-Boost or Power Lifting start a motor the station otherwise could not?
No. The boost modes raise the ceiling for resistive heating loads by reducing voltage, and EcoFlow's manual limits X-Boost to heating-type devices, warning that voltage-protected devices may stop working at the reduced voltage. A motor start is a surge question, and the only figure that answers it is the surge rating. Our comparisons print boost wattage and surge wattage as separate numbers so the two are never added together by mistake.
My station's surge rating is below my fridge's starting watts. What actually happens?
The compressor tries to start, cannot get the current it needs, and the station's overload protection cuts the output, or the compressor stalls and gives up. The battery is not harmed and the charge is not used up; the pairing simply does not work. Size motor loads against the surge rating first, and capacity second.