Home / Glossary hub
The resilience terms, defined
The words on the boxes, in the standards, and across this site, defined in one place. Each entry says what the term means, names the standard, agency, or maker behind the definition where one exists, and links to the page on this site that works the term through. Where a term is this site's own working usage rather than a standard, the entry says so.
Affiliate disclosure: Power & Pantry is reader-supported, and some links on this site are affiliate links that may earn us a commission at no extra cost to you. No product is sold from this page, and no affiliate links are live on it. See the About page for how we work.
How to read this page. Definitions checked November 2026. Where a term has a governing definition, in a standard, a regulation, or an agency's published guidance, the entry follows that source and names it. Where a term is this site's own planning usage, usable capacity is the main one, the entry labels it as ours and links the page that establishes it. A short section near the end names the terms whose meanings are not settled, because a glossary earns its keep partly by refusing to pretend a contested word is a settled one.
Power: watts, batteries, and the box
The power pages run on two pairs of numbers, watts against watt-hours and running against starting, and on a battery vocabulary the boxes print without defining. These are the terms as the standards, the agencies, and the makers define them, plus the one figure that is this site's own.
| Term | What it means | Worked through on |
|---|---|---|
| Amp-hour (Ah) | A measure of electric charge: a current multiplied by the hours it flows. Amp-hours become energy only when multiplied by the battery's voltage (watt-hours = amp-hours × volts), so two batteries rated in amp-hours at different voltages cannot be compared until both are converted. This site rates storage in watt-hours throughout, for that reason. | Generator wattage calculator |
| Backfeeding | Feeding generator power into house wiring by plugging the generator into a wall outlet. The power travels out toward the grid as well as into the house, and the American Red Cross and Hawaiian Electric both name the result: an electrocution risk to utility workers and neighbors. | Generator safety |
| Boost mode | A power station mode (Bluetti calls it Power Lifting, EcoFlow calls it X-Boost) that raises the ceiling for resistive heating loads above the continuous rating by trimming the output voltage. It is not surge capacity and adds nothing to motor starting; EcoFlow's own manual limits X-Boost to heating devices. | Starting watts vs running watts |
| Cycle | One full discharge and recharge of a battery. A cycle-life rating counts how many cycles a battery can deliver before its capacity fades to a stated fraction of what it held when new. See End-of-life threshold. | LiFePO4 vs lithium-ion |
| Duty cycle | The share of time a device actually runs, as opposed to sitting idle between runs. A refrigerator's compressor runs about half the day: at 150 W running draw and about a 12-hour daily duty cycle, a typical fridge uses 1,800 watt-hours a day, and a runtime figure that assumes full draw around the clock overstates its appetite by about double. | Fridge runtime |
| End-of-life threshold | The capacity fraction a maker's cycle count is measured down to. Bluetti, EcoFlow, and Goal Zero count to 80 percent of original capacity; Jackery counts its LiFePO4 models to 70 percent, per the makers' published specifications. Counts measured to different finish lines are not directly comparable, and the threshold is a fade milestone, not a death date: the station keeps working as a smaller station. | LiFePO4 vs lithium-ion |
| LiFePO4 (LFP) | Lithium iron phosphate, one cathode chemistry inside the lithium-ion family, not a rival to it: Battery University lists it among the six common lithium-ion types, and the US Department of Energy covers it in its lithium-ion safety plan. At cell level, Battery University's published averages give it 2,000 or more cycles and a thermal runaway threshold of about 270°C, against fewer cycles and lower thresholds for the nickel family. | LiFePO4 vs lithium-ion |
| Locked-rotor amps (LRA) | The current a motor draws at the instant of switch-on, while its shaft has not yet begun to move, printed on the appliance's rating plate next to its running current (RLA). Starting watts are the locked-rotor amps multiplied by the voltage on the same plate, which is why the nameplate figure governs and published charts are only planning figures. | Starting watts vs running watts |
| NMC | Lithium nickel manganese cobalt oxide, the nickel-family cathode chemistry. It is what the bare words "lithium-ion" usually hide on a spec sheet: Battery University's cell averages give it 1,000 to 2,000 cycles and a thermal runaway threshold of about 210°C, with more energy per kilogram than LiFePO4 and fewer cycles. | LiFePO4 vs lithium-ion |
| Pure sine wave | An inverter output shaped as the smooth wave of wall power, as against a stepped approximation. Station makers advertise it as the gentler output for electronics. It is a statement about the station's output only: it does not amend another maker's instruction, and a heated blanket manual that prohibits inverters gives no exception for any waveform. | Heated blanket runtime |
| Running watts | What an appliance draws once it is up and going, hour after hour, in Generac's published definition. Running watts multiplied by hours decide how long a battery lasts. A load with no motor, a kettle, a lamp, a heater, has only this number: it starts at its running watts and stays there. | Starting watts vs running watts |
| Starting watts (surge watts) | The much larger burst a motor draws for the first few seconds while it gets turning; Generac puts the extra demand at typically two to three seconds. The same figure is sold as surge watts and peak watts, and on gas generators as maximum watts against rated watts. Starting watts decide whether a motor turns over at all and barely register in energy terms. Published figures for the same appliance disagree widely, 800 to 2,200 W for a household fridge across the charts this site checked, so the nameplate's locked-rotor amps govern. | Starting watts vs running watts |
| Thermal runaway | The US Department of Energy's term for the primary safety concern in lithium-ion batteries: an accelerating release of heat inside a cell that becomes an uncontrollable rise in temperature. Each chemistry has a threshold temperature at which it begins, and LiFePO4's sits about 60°C above NMC's in Battery University's averages. | LiFePO4 vs lithium-ion |
| Transfer switch | A switch, installed by a qualified electrician, that connects a generator to selected house circuits while disconnecting the house from the grid, so generator power cannot travel out to the lines. The American Red Cross calls it the only recommended method of powering house wiring from a generator. | Generator safety |
| Usable capacity | This site's working figure, not a standard: the share of a power station's rated watt-hours a household can plan on using, computed as the rated capacity multiplied by 0.85, an inverter-efficiency factor. Every runtime on this site is arithmetic on usable capacity, and the factor is disclosed wherever it is used. | Generator wattage calculator |
| Watt and watt-hour (W and Wh) | A watt is a rate: how fast electricity is being drawn at a moment. A watt-hour is an amount: the watts multiplied by the hours they run. Battery capacity is printed in watt-hours, appliance draw in watts, and runtime is the division of the first by the second. | Generator wattage calculator |
The grid: how outages are counted
The statistics hub counts outages in the grid's own vocabulary. The three indexes are the US Energy Information Administration's, collected from utilities on Form EIA-861, and the fourth term is the standard that decides which days count as storms.
| Term | What it means | Worked through on |
|---|---|---|
| CAIDI | The average minutes it takes to restore one interruption, in the US Energy Information Administration's definition. Where SAIDI says how much outage a year holds and SAIFI says how often, CAIDI says how long each one lasts once it starts. | Statistics hub |
| Major event day | Under the IEEE 1366 standard, a day when storm damage passes a statistical threshold. Utilities reporting under that standard publish every reliability figure two ways, with major event days and without, and the two columns tell different stories: the without column is the routine grid, and the with column is mostly weather. | Statistics hub |
| SAIDI | The minutes of non-momentary interruption per year the average customer experienced, in the US Energy Information Administration's definition. It is the headline outage-duration figure in this site's statistics. | Statistics hub |
| SAIFI | The number of non-momentary interruptions per year the average customer experienced, in the US Energy Information Administration's definition. | Statistics hub |
Water: filters, standards, and treatment
Water treatment is sold in standards numbers and micron ratings, and both hide their definitions in footnotes. These entries print the definitions the standards and the makers themselves publish.
| Term | What it means | Worked through on |
|---|---|---|
| Absolute micron rating | A filter rating that names the largest particle that passes, with retention at that size up around 99.9 percent or better. The CDC names absolute 1-micron filters, and filters certified to NSF/ANSI 53 for cyst reduction, as the greatest assurance against Cryptosporidium. | Catchment filters and UV |
| Cyst | The dormant, hard-shelled form of certain protozoan parasites. Per the CDC, Cryptosporidium oocysts run about 4 to 6 microns across and Giardia cysts about 8 to 12. Both shrug off chlorine at the doses a storage tank carries, which is why the defense against them is a barrier they cannot fit through, or UV. | Catchment filters and UV |
| Log reduction | A tenfold step in how much of an organism a treatment removes or inactivates: a 1-log reduction is 90 percent, 3-log is 99.9 percent, and 4-log is 99.99 percent, the percentages printed in the US Environmental Protection Agency's UV dose table (40 CFR 141.720). | Catchment filters and UV |
| Nominal micron rating | A filter rating that describes stopping most particles at the stated size, not all of them. Pentair, the standard example in this market, prints the definition on its own spec sheets: its micron ratings are "based on 85% or greater removal of given particle size." A nominal rating is normal for sediment duty; for a barrier against a specific organism, the word in front of the number is the specification. | Catchment filters and UV |
| NSF/ANSI 42 | The drinking-water standard for aesthetic effects: taste, odor, chlorine, and particulate. Some products are certified under it for material requirements only. A Standard 42 listing is not a health-effects claim. | Gravity filters after Berkey |
| NSF/ANSI 53 | The drinking-water standard for health effects. A product is certified only for the claims listed for it, such as lead, total PFAS, or cyst reduction, and its cyst claim means a reduction of at least 99.95 percent of parasitic cysts, per the standard's own text. | Gravity filters after Berkey |
| NSF/ANSI 372 | The standard under which a product's materials are certified for lead content. It is a statement about what a product is made of, not about what it removes from the water passing through it. | Gravity filters after Berkey |
| NSF/ANSI 401 | The drinking-water standard for emerging compounds and incidental contaminants, the category that includes microplastics and traces of pharmaceuticals and pesticides. | Gravity filters after Berkey |
| Turbidity | The cloudiness of water, caused by suspended particles, measured in NTU (nephelometric turbidity units). Hawaii's Department of Health sets its catchment screening level at turbidity of 5 NTU or less, alongside E. coli absent and limits for lead and copper. | Catchment maintenance |
Catchment: the treatment train's words
The catchment pages add a treatment train of their own, roof to tank to taps, and its words come from CTAHR, the Hawaii Department of Health, and the UV standard.
| Term | What it means | Worked through on |
|---|---|---|
| First-flush diverter | A fitting that sends the first wash of water off a roof aside, away from the tank, on purpose: that first water carries the particles, mold, and pollen that accumulated on the roof since the last rain. CTAHR reports recommended diversion amounts from 10 to 49 gallons per 1,000 square feet of roof, with dirtier environments at the high end. | Hawaii catchment guide |
| NSF/ANSI 55 Class A | The UV standard's disinfection class: systems delivering a dose of at least 40 mJ/cm², built to disinfect water that may be contaminated, and required to carry a UV sensor, an alarm, and a flow restrictor so the water cannot outrun the dose. Wells, surface water, and catchment are Class A work. | Catchment filters and UV |
| NSF/ANSI 55 Class B | The UV standard's supplemental class: systems delivering 16 mJ/cm², designed for supplemental bactericidal treatment of water that has already been disinfected or deemed acceptable by the health agency with jurisdiction. Class B is not a failed Class A; it is a certification for a different starting point, one a catchment tank does not provide. | Catchment filters and UV |
| UV dose | The amount of ultraviolet light water actually receives in a UV unit: the light's intensity multiplied by the seconds of exposure, measured in millijoules per square centimeter (mJ/cm²). Dose falls as flow rises, as the lamp ages, and as the water gets less clear, which is why makers quote flow rates at a stated dose. | Catchment filters and UV |
| UVT (ultraviolet transmittance) | The share of UV light that passes through the water being treated. Makers quote a unit's flow at a stated UVT; cloudier water transmits less light, receives less dose at the same flow, and makes the same unit effectively smaller. | Catchment filters and UV |
Food storage: packaging words
The food pages pack dry goods against oxygen and time, and the packaging carries a small vocabulary of its own, most of it set by Utah State University Extension's guidance.
| Term | What it means | Worked through on |
|---|---|---|
| Mylar | A trade name for polyester (PET) film, used generically for food-storage bags. The bags themselves are a laminate of PET and foil, and it is the foil layer that cuts the passage of oxygen and moisture, per Utah State University Extension's packaging guidance. | Mylar bags and oxygen absorbers |
| Oxygen absorber | A small packet, iron powder and salt, sealed inside a container of dry food to remove its oxygen; Utah State University Extension puts the result at 0.01 percent oxygen or less, the rest effectively nitrogen. Its size is printed in cc, the cubic centimeters of oxygen it can absorb. The extension baseline is 50cc for a quart container, 300cc for a gallon container or a #10 can, and 1,500cc for a 5-gallon container; bag makers size higher, for airy foods in oversized bags. | Mylar bags and oxygen absorbers |
| Water activity | The water in a food that is available to microbes, as distinct from the food's total moisture. Freeze-drying brings water activity to about 0.3 or below, low enough that bacteria and mold cannot grow, per Utah State University Extension. | Freeze dryer vs dehydrator |
Radios and shielding
The comms and EMP corners speak in licenses, alert codes, and decibels. The license terms are the FCC's, the alert terms are the Weather Service's, and the decibel ladder is the Department of Homeland Security's.
| Term | What it means | Worked through on |
|---|---|---|
| Decibel (dB) | The unit shielding is measured in: how much a barrier cuts a signal's power. The scale is logarithmic, and the US Department of Homeland Security's EMP guidelines print the ladder: 20 dB of attenuation cuts signal power by a factor of 100, 40 dB by 10,000, 60 dB by 1,000,000, and 80 dB by 100,000,000. | Do faraday bags actually work? |
| Faraday cage and faraday bag | A closed shell of conductive material that keeps radio energy from crossing it. The cage is the rigid form, from a cabinet to a room; the bag is the same shell made flexible. The difference is scale, not technology: one maker builds a $23 phone pouch and a walk-in tent starting at $20,990 from the same fabric, with the same stated figure of 80 dB or more. The shell has to be continuous; a gap in it is a door. | Faraday cage vs faraday bag |
| FRS (Family Radio Service) | The license-free two-way radio service under the FCC's Part 95 rules. FRS shares its 22 channels with GMRS, at lower power, with antennas that cannot be swapped and no repeaters, which is the headroom GMRS exists to add. | Off-grid communication options |
| GMRS (General Mobile Radio Service) | The licensed two-way radio service under FCC Part 95, built for a household's own people: a $35 license lasting 10 years, no exam, covering the holder's immediate family. Handhelds may transmit at up to 5 watts, antennas may be removable, and repeaters are allowed. | Off-grid communication options |
| Public Alert | A certification standard for weather radios, written by the Consumer Technology Association together with the National Weather Service, which suggests looking for its logo. Devices carrying the logo include SAME technology, battery backup, and a tone alarm. The label alone does not settle whether a given radio decodes SAME; some certified radios do not. | Best emergency radios |
| SAME (Specific Area Message Encoding) | The digital code at the head of a NOAA Weather Radio alert that names the counties it applies to. A radio with SAME reads the code and sounds only for the counties programmed into it, instead of every watch and warning across the transmitter's whole footprint. | Best emergency radios |
Air: respirator classes
These two entries are worked through on this site's air page, the wildfire smoke purifier comparison, which covers respirators only as they apply to smoke and ash particles. One limit covers both classes: they filter particles only, and neither filters gases. That is why Hawaii's Department of Health does not recommend respirators for vog: a respirator stops ash and particulates, not the sulfur dioxide gas in vog.
| Term | What it means | Worked through on |
|---|---|---|
| KN95 | A respirator class under China's GB 2626-2019 standard: the KN series covers non-oily particles, and the 95 requires at least 95 percent filtration efficiency. It is a counterpart to the N95 under a different scheme, with different test methods; NIOSH does not approve KN95 products, and the two labels are not interchangeable certifications. | Best air purifiers for wildfire smoke |
| N95 | A respirator class approved by the National Institute for Occupational Safety and Health (NIOSH) under the federal regulation 42 CFR Part 84. The N marks a filter that is not resistant to oil, and the 95 means it filters at least 95 percent of airborne particles. | Best air purifiers for wildfire smoke |
Where the words are not settled
A glossary also owes its readers the list of terms that sound settled and are not. These are named here so no reader takes a contested word as a closed one:
- "Lithium-ion" standing alone. The bare label names the family and hides the member. The cathode name is the definition that matters, and it lives in a maker's battery details, not in its headline.
- Starting watts. No settled published figure exists: the charts this site checked put a household fridge's start between 800 and 2,200 W. The locked-rotor amps on your own appliance's plate are the governing number.
- "Nominal." The word is defined maker by maker. Pentair's 85 percent footnote is the printed example this site follows, not an industry-wide test every nominal rating has passed.
- Cycle counts. A count is not settled until its finish line is read with it: 80 percent of original capacity for most makers, 70 percent for Jackery's LiFePO4 models.
- Surge, peak, and maximum. Three labels for the one starting figure, against rated for the running one. Two products seem to disagree most often because each printed a different label.
Citing this page: Power & Pantry, "The resilience terms, defined," powerandpantry.com/glossary/, definitions checked November 2026. Each entry names its own source next to the definition; cite the original standard or agency where your use allows it, and this page for the collection.
Our data basis: the power definitions follow Generac's and Honda's published sizing guidance and the US Department of Energy's motor systems and energy-storage documents; the battery figures are Battery University's (Cadex) published cell averages, checked November 2026, and the makers' published specifications for the cycle-count finish lines. The grid indexes are the US Energy Information Administration's, from the Electric Power Annual and Form EIA-861. The water definitions follow the text of NSF/ANSI Standards 42, 53, 55, 372, and 401, the CDC's water guidance, Pentair's published spec-sheet footnotes, and the US Environmental Protection Agency's UV dose table at 40 CFR 141.720. The catchment terms follow the University of Hawaii CTAHR guidelines (revised 2020) and the Hawaii Department of Health's catchment guidance. The food terms follow Utah State University Extension. The radio terms follow the FCC's Part 95 rules, the National Weather Service, and the Consumer Technology Association's Public Alert standard. The shielding figures follow the Department of Homeland Security and CISA EMP guidelines, Version 2.2, February 5, 2019, and MOS Equipment's published lab results. The respirator classes follow the NIOSH regulation at 42 CFR Part 84 and China's GB 2626-2019 standard. Nothing on this page is presented as measured or tested by us.